TM 5-3895-374-10
No.
Panel
Value
Operation
NOTE
Switch will illuminate and when the compressor reaches the high pressure set point, the motor
will stop and the light will go out. This will light only when the compressor is running. When air
pressure is up and the compressor shuts off the light will go out. This confirms that the air
pressure switch is working. (Panel B)
27
B
Motor control panel-depress the START button on the
Hot Mix Convevor (the light will illuminate after a short
delay).
28
B
Motor control panel-check hot mix conveyor load meter
to verify loading of the conveyor motor.
NOTE
This motor will draw high amps until the slat is warmed up.
29
B
Motor control panel-depress START on the Drum Drive
(the light will illuminate after a short delay).
30
A
Feeder panel-depress the START button on the Feed
Conveyor (light will illuminate immediately).
NOTE
These units should run for a minimum of 15 minutes to warm up both conveyors.
31
B
Motor control panel-turn the Surqe Bin Heat selector
switch to ON (the light will illuminate).
32
B
Motor control panel-press the START button on the
Exhaust Fan (the light will illuminate after short delay).
NOTE
Observe the ammeter to verify the amperage draw (light will illuminate after a short delay). (Panel
B)
33
B
Motor control panel-press the Baqhouse Fines Blower
START button (light will illuminate).
Page 2-103