TM 5-3895-374-10No.PanelValueOperationNOTEThe outlet temperature is controlled by the hot oil heater16CCorner panel-the outlet temperature should be greaterthan the inlet temperature if heater is operating.NOTEAs the asphalt temperature reaches the desired temperature the inlet and outlet temperatures willbe within a degree or two of each other. The heater will automatically cut-off. (Comer Panel)17AFeeder panel-select DIVERT on the DivertSwitch.18AFeeder panel-select FORWARD on the AsphaltMeterinqPump.19AFeeder panel-select MANUAL on the manual autoselector switchAsphaltMeterinqPump.20AFeeder panel-adjust speed on the dial indicator toapproximately 50% ManualSpeed.21ScreenVerify pump is pumping asphalt by checking themonitor.22ScreenThis will appear in the second information line from thetop (it reads asphalt).23Screen260 toThe temperature of the asphalt will be displayed in the300Flast column.24Circulate asphalt for a minimum of 10 minutes to warmup pump and valves.25VisualVerify that the batcher gate is open.CheckNOTEThe main gate should be closed (visual check).26BMotor control panel-turn Surqe Bin Air compressor andBaqhouseAir compressor to the ON position.Page 2-102