TM 5-3895-374-10No.PanelValueOperation55AFeeder panel-select AUTO on the Divertswitch (verifythat the Divert light continues to be illuminated).56AFeeder panel-select AUTO on the four Feeder switches.57AFeeder panel-press START on the ScalpingScreenbutton (the light will illuminate).58AFeeder panel-press START on the GatheringConveyorbutton (the light will illuminate).59KeyboardKeyboard-press ESCAPE, select targets (1), enterstarting feed rate-80 tons per hour, press ENTER.60ScreenSelect desired mix formula (this must be pre-determinedand entered into the controller), ENTER.61A, B, DCheck all control panels to verify all motors are running(no flashing lights).62KeyboardKeyboard-press ESCAPE the feeders will start insequence.63AFeeder panel-verify that the selected feeders arerunning.64AFeeder panel-check the feeder selector switch lights.65DBurner control panel-when materiel begins to enter drum,slowly increase burner firing rate by depressing the UPARROW on the StackControl.66D300 FBurner control panel-increase until stack control readsapproximately 300°.67DBurner control panel-maintain at this temperature byincreasing (UP ARROW) or decreasing (DOWNARROW) the burner firing rate on the StackControl.page 2-106