TM 5-3895-374-10After plant movement requires the above to be completed methodically and carefully. Shifting of plant components ordamage to them may occur during transportation and not be visible until plant operation. The set up on a plant site mayresult in components not properly supported or positioned with the result that the plant may not operate correctly. Monitorthe components carefully while completing the above procedures and correct any problems before full plant production isattempted. Before proceeding with production of asphalt hot mix, the operator should be familiar with the operation of thesurge bin. See section 2-19 for instructions.2-13 Plant Start UpNOTEOperation of the plant is much easier if the plant is started at the same production rate each time.If a high or lower production rate Is desired, the Increase and decrease procedures should be usedafter the initial start up Is accomplished. The Initial start up is established at the rate of 80 tonsper hour.NOTEIn the "Operation" column of the following tables the control switches or buttons are shownunderlined. This corresponds to the labels on the control panel. The function to be performed bythe switch or button is indicated in CAPITAL letters.NOTERefer to Figures 33-36 to aid in locating controls on panels.Plant Start UpNo.PanelValueOperation1MCC 1Turn main breakers OFF.MCC 22Start the two 200 kW generator sets as per themanuals.3Bring the generator sets to 460 volts-60cycle.4Close main contacts on the two generator sets.5AFeeder panel-confirm Power key is OFF.page 2-100