TM 5-3895-374-10No.PanelValueOperation44DBurner control panel-select STACK on ControlMode.45DBurner control panel-select MainFlameSTART andrelease (this is a momentary contact switch-main firewill ignite after a delay of approximately 15 secondsand MainFlameProved light will illuminate).46D< 300FBurner control panel-select MANUAL on StackControl(this will indicate the temperature of the exhaust airexiting the drum mixer).47DBurner control panel-manually increase burner firingrate by depressing the UP ARROW on the StackControl.48D250 FBurner control panel-maintain the temperature atapproximately 250 by increasing or decreasing(depress the UP-DOWN ARROW on the StackControl) the burner firing rate for approximately 15 to20 minutes.49D200 FBurner control panel-monitor the BaghouseExhaustTemperatureon the display (when it reaches atemperature of 200° the preheat is complete).50BMotor control panel-reject materiel in the surge bin intoa truck or front end loader.51BMotor control panel-select OPEN on the DischargeGate(the open light will illuminate).52BMotor control panel-select CLOSE when the bin isempty.53BMotor control panel-set Batcher to the AUTO position(the gates will close and then cycle open and closed.Openand Closelights will illuminate).54AFeeder panel-select AUTO on the AsphaltMeteringPumpswitchpage 2-105