TM 5-3895-374-10
No.
Panel
Value
Operation
44
D
Burner control panel-select STACK on Control Mode.
45
D
Burner control panel-select Main Flame START and
release (this is a momentary contact switch-main fire
will ignite after a delay of approximately 15 seconds
and Main Flame Proved light will illuminate).
46
D
< 300F
Burner control panel-select MANUAL on Stack Control
(this will indicate the temperature of the exhaust air
exiting the drum mixer).
47
D
Burner control panel-manually increase burner firing
rate by depressing the UP ARROW on the Stack
Control.
48
D
250 F
Burner control panel-maintain the temperature at
approximately 250 by increasing or decreasing
(depress the UP-DOWN ARROW on the Stack
Control) the burner firing rate for approximately 15 to
20 minutes.
49
D
200 F
Burner control panel-monitor the Baghouse Exhaust
Temperature on the display (when it reaches a
temperature of 200° the preheat is complete).
50
B
Motor control panel-reject materiel in the surge bin into
a truck or front end loader.
51
B
Motor control panel-select OPEN on the Discharge
Gate (the open light will illuminate).
52
B
Motor control panel-select CLOSE when the bin is
empty.
53
B
Motor control panel-set Batcher to the AUTO position
(the gates will close and then cycle open and closed.
Open and Close lights will illuminate).
54
A
Feeder panel-select AUTO on the Asphalt Metering
Pump switch
page 2-105