TM 5-3895-374-24-1
Configuration, special functions, settings
Settings
Parameters
Values
Factory setting
Descnption
Frequency loop gain
0 to 100
33
Only with voltage / frequency ratio set on F or L
Enables adjustment of the speed controllers
response time
- 0 to 33
: longer response time
- 33
: factory setting
- 33 to 100 : shorter response time
Applications:
- machines with high resistive torque or high
inertia adjust the frequency loop gain In the 0
to 33 zone.
- machines with fast cycles, low resistive torque
or low inertia adjust the gain In the 33 to 100
zone.
Precaution: excessive gain can lead to
unstable operation.
Skip frequency 1
0 to high speed
High speed
Adjustment : affects the speed reference in
order to determine the 1 or 2 critical frequen-
Skip frequency 2
cies, (noise or mechanical vibrations)
Adjust the skip frequencies 1 (and 2) on the
value (or values) read.
If resonance persists, widen the skip frequency
band from 2 to 5 Hz, see special function
frequencies" p 89.
I thermal 2
0,2 to 1,05 In
0,9 In
DC braking level current
0,2 to 1,5 In
0,5 In
DC Injected permanently when the DCB input
Is validated (after Impulse of 1,5 In for
3 seconds).
Value In amps, variable according to the speed
controller rating.
DC stop level current
0,5 to 1,5 In
In
DC injected permanently when the frequency
drops to < 1 Hz.
Value in amps, variable according to the speed
controller rating.
DC stop time
0,5 to 4 s
0,5 s
DC injection time when the frequency drops to
<1 Hz.
Brake control threshold
0 to In
0
Current threshold authonzing closing of the
brake control relay (on braking and speed
regulation option).
In speed controller rated current (p 10 and 11)
(page 3-244)