TM 5-3895-374-24-1
Configuration, special functions, settings
Special functions
Functions
Selection
Factory settingDescription
Ramps
Linear
Linear
Types of acceleration and deceleration ramps
S
The use of ramps S (rounded ramps) or
Parabolic
parabolic ramps increases the real acceleration
and deceleration times
Linear
Adjustments: see acceleration and decelaration
parameters, p 92
Deceleration ramp
Yes / No
Yes
Deceleration ramp adaptation automatically
adaptation
No braking module
increases the deceleration time, if the latter
was set to too low taking into account the load
inertia.
This function can be disabled in the event of a
braking option being used, to obtain maximum
braking performance
in the event of there being no braking option,
the selection of No braking module enables, in
most cases, avoiding locking due to overbra-
king ( 0bF ), even if the deceleration ramp is
not adapted to the load
Skip
No
No
It is possible to skip two 2 or 5 Hz frequency
frequencies
2 Hz 5 Hz
bands
Aim to stop the motor from operating perma
nently at machine or installation resonant fre
quencies
Positioning of the 2 frequency bands
see "Skip frequencies 1 and 2" p 93
(page 3-240)