TM 5-3895-374-24-1
Commissioning terminal
Parameters which appear
Explanations
on the screen
Reduce I lim
Reduction of the current limitation
Acceleration 2
Acceleration time, ramp 2
Deceleration 2
Deceleration time, ramp 2
Freq loop gain
Frequency loop gain
Skip freq. 1
Skip frequency n° 1
Skip freq. 2
Skip frequency n° 2
I thermal 2
Motor thermal current, value 2
DC brake current
DC brake current value
DC stop current
DC standstill current value
DC stop time
DC current injection time on stop
Brake release I
Current threshold for mechanical
brake control
Brake release F
Frequency threshold for mechanical
brake release
Brake engage F
Frequency threshold for mechanical
brake engage
Brake relay delay
Time delay for mechanical brake release
A detailed description of these parameters can be found In the chapter "Configuration, special func-
tions, settings" (pages 92 to 94)
(page 3-260)