TM 5-3895-374-24-1
Commissioning Terminal
8-TERMINAL CONTROL
The terminal control mode enables the speed controller to operate Independently from its logic or
analogue inputs.
The speed controller must be on stop for the terminal control to be validated.
CAUTION check that the motor drive presents no danger for personnel, as the speed controller does not
take into account the driven machines safety devices.
Procedure:
Display time 4 seconds
Validation of terminal control
In this case, the terminals keys are reassigned as follows
ENT
RUN
Run command
PAR
FW/RV
Change rotation direction
DAT
STOP
Stop with deceleration ramp
+
Increase the setspeed
-
Decrease the setspeed
STP
Locking the speed controller, freewheel stop
CLR
ESC
Escape - Cancellation of terminal control when the speed controller Is on
stop.
Display of electrical quantities (setspeed, current, thermal state,
frequency, load, mains supply), when the speed controller Is operating.
(page 3-263)