TM 5-3895-374-24-1
Commissioning terminal
Descnption of the
1-CONFIGURATION
control and adjustment
This mode enables display and adjustment of the configuration parameters
modes
The parameters can only be modified when the speed controller is on stop
List of the parameters which
Speed
Explanations
appear on the screen
controller
code
Nominal freq
Fr5
Nominal motor frequency
Current input
rE
Volts/Freq
UF
Voltage / frequency
Max frequency
Fr
Maximum frequency
Slip compens.
SLP
Slip compensation
Preset speeds
Preset speeds
+ speed/-speed
Faster / slower
Reduce volts FW
Reduction of voltage (forward)
Reduce volts RV
Reduction of voltage (reverse)
Reduce 1lim.
Reduction of current limitation
Accel. torque
Reduction of current limitation, only
when not accelerating (the torque is not
reduced during acceleration)
A detailed description of these parameters can be found In the chapter "Configuration,
special functions, settings" (pages 81 to 83)
(page 3-256)