No.
Panel
Value
Operation
9
D
Burner control panel-press STOP on Fuel Pump button (light will extinguish).
10
B
Motor control panel-press STOP on Exhaust Fan button (light will extinguish).
NOTE
The baghouse fines blower, airlock, discharge incline screw, transfer screw and hopper screws will stop and pilot
light will extinguish.
NOTE
Baghouse bag cleaning will cycle for a 5 minute period prior to shutting off.
11
B
Motor control panel-press STOP button on Hot Mix Conveyor (conveyor will stop
after a 30 second delay). This will cause the drum, feed conveyor, scalping screen,
and gathering conveyor to stop and pilot lights to extinguish.
12
B
Motor control panel-select OPEN on the Batcher switch.
13
B
Motor control panel-select OFF on the Surqe Bin Heat switch.
14
B
Motor control panel-select OPEN on the Discharge Gate switch when the bin is
empty.
15
B
Motor control panel-select OPEN on the Batcher switch.
NOTE
Proceed with the following steps only after the surge bin has been emptied. For operation of the surge bin see
section 2-19.
16
B
Motor control panel-select OFF on the Surqe Bin Air switch.
17
B
Motor control panel-select OFF on the Baqhouse Air switch.
18
A
Feeder panel-select Asphalt Meterinq Pump REVERSE then MANUAL (motor
should run at 50% speed on the meter. Adjust on Manual Speed if necessary )