TM 5-3895-374-10
No.
Panel
Value
Operation
13
-START the following motors as quickly as possible in
the following order:
B
Motor control panel-Drum Drive-f
A
Feeder panel-Feed Conveyor
A
Feeder panel-Scalpinq Screen
A
Feeder panel-Gatherinq Conveyor
A
Feeder panel-verify the selected feeders start
automatically
A
Feeder panel-verify divert valve returns to
Drum position
D
Burner control panel-select AUTO on the
stack controller by pressing MANUAL/AUTO.
NOTE
Monitor the mix discharging the drum to verify that it is acceptable.
NOTE
Reject any unacceptable mix by selecting OPEN on the Drop Out selector switch
(Panel B).
No.
Panel
Value
Operation
14
B
Motor control panel-START the following baghouse
motors:
Fines Blower
Airlock
Discharqe Incline Screw
Transfer Screw
Hopper Screw
NOTE
Monitor to the standard start up procedures.
2-18 Shut Down
NOTE
In a personnel emergency the plant may be shut down by PRESSING the Emergency Stop (red)
button on the comer panel. This will stop all equipment operations.
page 2-114