TM 5-3895-374-10No.PanelValueOperation13-START the following motors as quickly as possible inthe following order:BMotor control panel-DrumDrive-fAFeeder panel-Feed ConveyorAFeeder panel-ScalpinqScreenAFeeder panel-GatherinqConveyorAFeeder panel-verify the selected feeders startautomaticallyAFeeder panel-verify divert valve returns toDrumpositionDBurner control panel-select AUTO on thestack controller by pressing MANUAL/AUTO.NOTEMonitor the mix discharging the drum to verify that it is acceptable.NOTEReject any unacceptable mix by selecting OPEN on the DropOut selector switch(Panel B).No.PanelValueOperation14BMotor control panel-START the following baghousemotors:FinesBlowerAirlockDischarqeInclineScrewTransferScrewHopperScrewNOTEMonitor to the standard start up procedures.2-18 Shut DownNOTEIn a personnel emergency the plant may be shut down by PRESSING the Emergency Stop(red)button on the comer panel. This will stop all equipment operations.page 2-114
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business