TM 5-3895-374-10No.PanelValueOperation3BMotor control panel-press STOP button on DrumDrive.This will cause the drum, feed conveyor, scalpingscreen, gathering conveyor, and all selected feeders tostop and pilot lights to extinguish.4AFeeder panel-verify that the Divert valve light switchesfrom drum to DIVERT.5BMotor control panel-press STOP button on ExhaustFan. This will cause the following motors to stop. Thebaghouse fines blower, airlock, discharge inclinescrew, transfer screw, and the hopper screws. Thesepilot lights will be extinguished.6DBurner control panel-press STOP on the BurnerFanbutton.2-17 Hot StartThis procedure is used after a hot shut down has been performed. Plant production is resumed at the rate set prior to thehot shut dow n.No.PanelValueOperation1BMotor control panel-press START on the ExhaustFanbutton.2DBurner control panel-press START on the Burner Fanbutton.3DBurner control panel-select MANUAL on the StackControlManual/Auto.4DBurner control panel-LimitsClosed will illuminate,indicating that the exhaust fan, burner fan, and fuel pumpare running. Stack temperature is below the high (alarm)set point.5DBurner control panel-if limits is closed, PRESS LimitsSetand button will light .page 2-112
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business