TM 5-3895-374-10
No.
Panel
Value
Operation
3
B
Motor control panel-press STOP button on Drum Drive.
This will cause the drum, feed conveyor, scalping
screen, gathering conveyor, and all selected feeders to
stop and pilot lights to extinguish.
4
A
Feeder panel-verify that the Divert valve light switches
from drum to DIVERT.
5
B
Motor control panel-press STOP button on Exhaust
Fan. This will cause the following motors to stop. The
baghouse fines blower, airlock, discharge incline
screw, transfer screw, and the hopper screws. These
pilot lights will be extinguished.
6
D
Burner control panel-press STOP on the Burner Fan
button.
2-17 Hot Start
This procedure is used after a hot shut down has been performed. Plant production is resumed at the rate set prior to the
hot shut dow n.
No.
Panel
Value
Operation
1
B
Motor control panel-press START on the Exhaust Fan
button.
2
D
Burner control panel-press START on the Burner Fan
button.
3
D
Burner control panel-select MANUAL on the Stack
Control Manual/Auto.
4
D
Burner control panel-Limits Closed will illuminate,
indicating that the exhaust fan, burner fan, and fuel pump
are running. Stack temperature is below the high (alarm)
set point.
5
D
Burner control panel-if limits is closed, PRESS Limits Set
and button will light .
page 2-112