TM 5-3895-374-10
NOTE
At a production rate of 80 tons per hour proceed as follows:
No.
Panel
Value
Operation
1
Keyboard
Press ESCAPE-targets (1), zero (0), ENTER, ESCAPE
NOTE
Feeders will shut down in order.
NOTE
Monitor aggregate rate-it will decrease to zero as the last of the aggregate crosses the scale (Panel A).
2
D
250
Burner control panel-lower set point on stack control to 250.
3
D
Burner control panel-monitor stack temperature on stack control to ensure that it
does not exceed 300.
4
D
Burner control panel-turn Main Flame switch to OFF if the temperature does not
exceed 300.
5
A
Feeder panel-monitor divert valve to see that it returns to divert after the asphalt
shut down time delay has elapsed.
NOTE
Monitor hot mix exiting drum and reject any unacceptable mix by selecting OPEN on the Drop Out selector
Switch. (Panel B)
6
D
Burner control panel-continue to operate burner at 250 stack temperature for 5
minutes.
7
D
Burner control panel-Main Flame selector switch to OFF.
8
D
Burner control panel-press STOP on Burner Fan button (light will extinguish).
page 2-115