TM 5-3895-374-24-1
The Following
Probable Cause
Recommended Action
Error Exists
1. Check line power
Inadequate
2. Check 120/240V power supply jumper selection See
System Power
page 5-5 Also, see the recommended action for
for Inadequate System Power on page 9-12
Fatal Error and
Communication
Check communication channel configuration with APS
No
channel is shut
Also, see "Returning the 5/03 Processor to Its 'Initial
Communication
down.
Factory Conditions" on page 925
Communication
channel is
Replace processor
damaged
Channel
See the Advanced Programming Software User Manual
configured for
(Catalog Number 1747-NM002) for channel configuration
DF1
Information
Refer to the following key to determine the status
of the LED indicators
Indicates the LED is OFF
Indicates the LED Is ON
Indicates the LED Is FLASHING
Status of LED does not matter
Chapter 9
Troubleshooting
(page 3-451)