TM 5-3895-374-24-1The FollowingProbable CauseRecommended ActionError Exists1. Monitor program file online and Identifyprogrammed forcesSystem doesUser programmed2. Enable appropriate forces and test systemnot operate perforces are notconditions again Once forces are enabled, theprogrammedenabledFORCE LED goes on steadyforcesRefer to the Advanced Programming Software UserManual (1 747-NM002)The FollowingProbable CauseRecommended ActionError Exists1. Verify battery is connected See pages 51 and 8-52. Replace the battery See page 8-5CPU MajorLoss of RAMError with Lowduring Power3 Refer to processor major fault recommended actionor No BatteryDown PeriodstepsBack-upRefer to the Advanced Programming Software UserManual (1747-NM002)Refer to the following key to determine the statusof the LED indicatorsIndicates the LED Is OFFIndicates the LED Is ONIndicates the LED is FLASHINGStatus of LED does not matterRegardless of any other LED status Indicatorconditions, always replace the battery whenthe BATT LED Is on if you want RAM batterybackupChapter 9Troubleshooting(page 3-449)