TM 5-3895-374-24-1
Chapter 9
Troubleshooting
PROCESSOR ERRORS
Error
Code
Module Display
Fault Description
xx5A
SLOT xx SI/O ERR
Hardware interrupt problem at the specified slot.
xx5B
SLOT xx BAD CFG
G file configuration error - User program G file size
exceeds the capacity of the module
xx5C
SLOT xx BAD CFG
MO-M1 file configuration error - User program MO-M1
file size exceeds the capacity of the module.
xx5D
SLOT xx SI/O ERR
Interrupt service requested is not supported by the
processor.
xx5E
SLOT xx SI/O ERR
Processor I/O driver (software) error.
xx60
thru
xx6F
SLOT xx SI/O ERR
Identifies an I/O card specific recoverable major error.
Refer to the user Information supplied with the card for
further details.
xx70
thru
xx7F
SLOT xx SI/O ERR
Identifies an I/O card specific non-recoverable major
error. Refer to the user information supplied with the
card for further details.
xx80
thru
xx8F
SLOT xx SI/O ERR
Identifies an I/O card specific non-recoverable major
error. Refer to the user information supplied with the
card for further details.
xx90
SLOT xx MOD ERROR
Interrupt problem at the specified disabled slot.
xx91
SLOT xx MOD ERROR
The specified disabled slot has faulted.
xx92
SLOT xx INT ERROR
Invalid or non-existent module interrupt.
xx93
SLOT xx MOD ERROR
Unsupported I/O module specific major error.
xx94
MOD IN SLOT xx
In the processor run or test mode, a module has been
detected as being Inserted under power. Code xx94
also can mean that an l/O module reset itself.
page 3-407