TM 5-3895-374-24-1Chapter 9TroubleshootingTroubleshooting ProcessorIf you are attached to a processor when a fault occurs, the module displays aFaults Using the LCDfault code, in hexadecimal format, and a description of the fault. You may alsoattach to a faulted processor to view the source of a fault The tabIes belowdescribe the possible fault conditions In SLC 500 family processors.The characters xx in the following codes represent the slot number, in hex.The characters xx become IF if the exact slot can not be determined.Slot Numbers In HexadecimalSlotXXSlotXXSlotXX001108221610112OC231720213OD241830314OE251940415OF261A5051610271B6061711281C7071812291D8081913301E9092014100A2115PROCESSOR ERRORSErrorCodeModule DisplayFault Description0000NO FAULTYou have attempted to view a fault in a non-Faulted processor0001CORRUPT NVRAMNVRAM error0002HARDWARE TIMEOUTUnexpected hardware watchdog timeout.0003AUTOLOAD FAILEDMemory module memory error. This error canalso occur when gong to the REM Run mode.0007?TRANSFER FAILEDFailure during memory module transfer ofautoload.0008?CPU SOFTWARE ERRInternal software error0009?CPU HARDWARE ERRInternal hardware error0010WRONG PROC REVThe processor does not meet the properrevision level.0011FILE 2 MISSINGThe executable program file number 2 isabsent.0012PROG MEM ERRORThe ladder program has a memory error.0013MEM MOD MISSINGThe required memory module is absent oreither S 1/10 or S 1/11 Is not set as required bythe program.0014INT. FILE ERRORInternal file error.0015CFG. FILE ERRORConfiguration file error.Error codes for 5103 Processor onlypage 3-404
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business