TM 5-3895-374-24-2
4-5. Surge Bin
Problem
Cause
Solution/Reference
Batcher fails to open
Air pressure too low
Cylinder jammed
Solenoid
failure
Broken or disconnected
air lines
Cold asphalt in discharge
area
Cord failure
Control fuse blown
Selector switch failure
PLC failure
See PLC manual
Discharge gate fails
Air pressure too low
Cylinder jammed
Solenoid
failure
Broken or disconnected
air lines
Cold asphalt in discharge
area
Cable failures
Control fuse blown
Drop out gate
Air pressure too low
Cylinder jammed
Solenoid
failure
Broken or disconnected
air lines
Cold asphalt in discharge
area