TM 5-3895-374-24-2
4-8. Burner
Problem
Cause
Solution/Reference
"Limits on" light fails to
light
Panel not on
Limit failure
Blowers not operating
Pilot fails to light
Propane not available
Pilot valve not opening
Ignition not operating
Pilot lights but does not
continue (flame signal
low)
Pilot scanner not sensing
flame
Pilot flame weak
Scanner failed
Pilot lights but main flame
not lighting
Main fuel pressure low
Main fuel valve not
operating
Fuel pump stopped
No fuel in tank
4-9. Control System Interlocks
The M081 Asphalt Mixing Plant is a continuous mix process. This requires that equipment at the end of the process be
operational prior to the feed of raw materials. This is guaranteed through the use of electrical interlocks. The plant PLC
confirms that specific electric motors are operational prior to starting the feed of raw materials.
page 4 - 23