TM 5-3895-374-24-2
Problem
Cause
Solution/Reference
Cable failures
Control fuse blown
Gate heat not functioning
Breaker OFF in LP1
Selector switch OFF
Contactor CR236 failed in
surge bin J box
Thermostat failure
Heating element burnt out
Compressor fails to start
Selector switch OFF
Pressure switch failure
Control cable failure
Control fuse blown
PLC failure
See PLC manual
All other MCC checks
Hydraulic pump fails to
start
Control cable not
connected
Breaker OFF
Overload tripped
Control relay failure
Replace CR211
See electrical drawing
AA00309
Power cord not plugged in
Compressor fails to start
Control relay failed
Auxiliary contact failed
Pilot light flashing after
two seconds
Control wiring failure
Overload tripped
Bin level indicator does
not work
Cold asphalt prevents
shaft from turning
page 4 - 19