TM 5-3895-374-24-22. The correct load chain set up is that the weld of each link faceoutward as shown in Fig. 11. When you replace a load chain, setit up correctly with respect to the welds.Fig. 1112. Precautions concerning wiring workIn case cover is removed for wiring work, do not touch energizedparts with hand, as condensers are charged if energized onceeven after current supply is cut.After cutting power supply, never fail to press either of the pushbutton ÑÒ to discharge the condensers.(page 3 - 891)