TM 5-3895-374-24-1
Chapter 9
Troubleshooting
Troubleshooting
Communications Problems
Using the LCD
TROUBLESHOOTING CONSIDERATIONS
GENERAL ERROR
SCREEN
ATTEMPTED FUNCTION
PROBABLE CAUSES
RECOMMENDED ACTION
Attach to Node
Illegal Node Address
Entered
Node address must be within
the range of 0 through 31.
Change Processor to Run
Mode
Module Not Attached to
Node
Attach to proper node address
Module Not in Modify
Change module to Modify
mode
Mode
Display Fault
Module Not Attached to
Node
Attach to proper node address
Clear Fault
Module Not Attached to
Node
Attach to proper node address.
Module Not in Modify
Node
Change module to Modify
mode
Change Processor to
Program Mode
Module Not Attached to
Node
Attach to proper node address
Module Nod min Modify
Change module to Modify
mode
Mode
EEPROM to RAM
Memory Transfer
Module Not Attached to
Node
Attach to proper node address
Module Not in Modify
Mode
Change module to Modify
mode.
Processor In Run or
Test Mode
Change processor to Program
mode
RAM to EEPROM
Memory Transfer
Module Not Attached to
Node
Attach to proper node address
Module Not in Modify
Node
Change module to Modify
mode
Processor In Run, Test
or Fault Mode
Change processor to Program
mode or dear fault.
Processor Contains No
User Program
Download a user program to
processor from a programming
device, APS or HHT
page 3-398