TM 5-3895-374-10ItemProcedure10Extend the cylinders and lower the support base until the two pins in the columns can be re-inserted.11Lock the pins in place by re-inserting the clip pins.12Push the right control lever to extend and lower the two cylinders mounted on the front support base.13Extend the cylinders and lower the support base until the two pins in the columns can be re-inserted.14Lock the pins in place by re-inserting the clip pins.15Shut off the electrical switch on the surge bin hydraulic pump.16Using the hydraulic power pack and the control valve bank connected to it extend the levelling jacks to raise the unit approximately 1/4" off the ground.17Placing a four foot level on the main beams at the front and rear of the unit and using the hydraulics, adjust the hydraulic levelling jacks until the unit is level front to back.18Secure and lower the rear screw jacks to accept the weight of the unit.19Adjust the screw jacks on the rear support base.20Adjust the screw jacks on the front support base.21Retract the hydraulic levelling jacks to lower the unit so the weight is resting on the base pads.22Check the unit to ensure it is level front to back on both sides.23Check the unit to ensure it is level side to side on the front support base and on the rear support base.24Check the unit to ensure it is level side to side on the rear cross member.25If the unit is not level, repeat the necessary steps to level the unit.26DO NOT PROCEED UNTIL THE UNIT IS LEVEL.27Shut off the power for the portable hydraulic power pack and disconnect the hoses to the surge bin.28The air brake lines and transport lighting cables have connections in the drive through area. Disconnect the two gladhands, 12 volt cable and 24 volt cable from their receptacles. Retract the hoses and cables totheir storage location.page 2-17
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business