TM 5-3895-374-10options ..............utilities............................calibration .................................................METER CALIBRATIONS display<8><6><5>The Meter Calibrations display is shown in Figure 865.0Note that even though this display overwrites the entire MainOperating display, the plant operation and data gathering continues uninterrupted.The Continuation Options are:OPTIONSKEYDESCRIPTIONESCapeESCReturn to the previous display.Edit.00Gain access to the data shown so that one or more of the parameters canbe changed. Access cannot be obtained if the DATA KEY is in the DATALOCKED position.CalibrateRates byAvg Value2Display a running average of current actual readings from each scale andmeter. From this screen the operator can elect to run a 6 minute timedscale check with automatic printout or automatically adjust zero or spanvalues to known average values.Avg Scalesby Sample4Go to the procedure for calibrating aggregate scales to the measuredweight of a sample load.A/C meterby Sample6Go to the procedure for calibrating the asphalt meter to the measuredweight of a sample load.Screen Print9Print this screen display. The printer must be ON and SELECTed.page F - 65SYSTEMS Equipment Corp. 8/31/89 Page (35)
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business