TM 5-3895-374-10
options ..............utilities............................calibration .................................................METER CALIBRATIONS display
<8>
<6>
<5>
The Meter Calibrations display is shown in Figure 865.0Note that even though this display overwrites the entire Main
Operating display, the plant operation and data gathering continues uninterrupted.
The Continuation Options are:
OPTIONS
KEY
DESCRIPTION
ESCape
ESC
Return to the previous display.
Edit
.00
Gain access to the data shown so that one or more of the parameters can
be changed. Access cannot be obtained if the DATA KEY is in the DATA
LOCKED position.
Calibrate
Rates by
Avg Value
2
Display a running average of current actual readings from each scale and
meter. From this screen the operator can elect to run a 6 minute timed
scale check with automatic printout or automatically adjust zero or span
values to known average values.
Avg Scales
by Sample
4
Go to the procedure for calibrating aggregate scales to the measured
weight of a sample load.
A/C meter
by Sample
6
Go to the procedure for calibrating the asphalt meter to the measured
weight of a sample load.
Screen Print
9
Print this screen display. The printer must be ON and SELECTed.
page F - 65
SYSTEMS Equipment Corp. 8/31/89 Page (35)