TM 5-3895-374-10ItemProcedure33Calculate and compare sample weight with computer test weight. If in error, on keyboard, selecterror calculation (8), enter requested values as prompted. Record results on calibration sheet.Select correct totals (9), enter calibrated weight from calibration sheet. Press ESCAPE.34Repeat calibration procedure starting with 20 through 32. Repeat this process until asphaltmeter is within one half of one per cent.35Upon completion of testing, empty calibration tank completely.36Clean out hose by sucking approximately 2 or 3 gallons of cleaning product through the hoseinto the asphalt tank. Close valves on tanker. Remove hose and store. Cap inlet to calibrationtank and outlet on asphalt tanker.page 2-94