TM 5-3895-374-10
Item
Procedure
33
Calculate and compare sample weight with computer test weight. If in error, on keyboard, select
error calculation (8), enter requested values as prompted. Record results on calibration sheet.
Select correct totals (9), enter calibrated weight from calibration sheet. Press ESCAPE.
34
Repeat calibration procedure starting with 20 through 32. Repeat this process until asphalt
meter is within one half of one per cent.
35
Upon completion of testing, empty calibration tank completely.
36
Clean out hose by sucking approximately 2 or 3 gallons of cleaning product through the hose
into the asphalt tank. Close valves on tanker. Remove hose and store. Cap inlet to calibration
tank and outlet on asphalt tanker.
page 2-94