heater specifications
FUEL REQUIREMENTS

TM-5-3895-374-24-2 M081 Asphalt Mixing Plant Manual
Page Navigation
  239    240    241    242    243  244  245    246    247    248    249  
TM 5-3895-374-24-2 MINIMUM PIPE SIZE FOR HOT OIL CEI HEATER MODELS 500 800 1000 1500 2000 3000 4000 1.  Main Lines 2" 2" 2" 2" 3" 3" 3" 2.  Tank Circuits 2" 2" 2" 2" 2" 2" 2" 3.  Asphalt Pumps 1" 1" 1" 1" 1" 1" 1" 4.  Asphalt Plant 1" 1" 1" 1½" 1½" 1½" 1½" 5.  Hot Oil Jumper Lines 1" 1" 1" 1" 1" 1" 1" PIPE CAPACITIES-GALLONS PER FOOT Pipe Size 1" 1½" 2" 2½" 3" 3½" 4" Gal.  Per Foot. 05. 10 17 .25 .38 .52 .66 INSTALLING JACKETED PIPE In piping for heating with oil, please keep in mind that to assure good circulation and avoid air locks, always route the piping so that the flow is into any jacket or part of system at the lowest point and out at the highest point.  For example, a jacketed line that runs horizontally should be as shown below: page 3-924