TM 5-3895-374-24-2
4-4-3. Temperature Device
Problem
Cause
Solution/Reference
Temperature display
reads high
Thermocouple not
connected
Thermocouple lead
broken
Thermocouple failure
Temperature display
reads low
Cable shorted
Poor connections
Failure of thermocouple
Hot mix build up on
temperature probe
Temperature display
erratic (changing)
Cable shorted
Broken wire or
connections
Contaminated contracts
on J-P connections
Moisture in J boxes
4-4-4. Control Panel
Problem
Cause
Solution/Reference
All controls not working
Control power
disconnected
Check voltage at terminal
block TB100
TB 1-3 = 120Vac
TB 2-3 = 120Vac
See electrical drawing
AA00303