TM 5-3895-374-24-2
Problem
Cause
Solution/Reference
Output module failure on
asphalt computer
Check output module on
blend I/O strip module #16
See electrical drawing
AA00314
Output module failure on
A/B PLC SLC500
Check output #12 on
Card #12
Number 12 should be
illuminated when divert
selector is in divert
position
See electrical drawings
AA00374 and AA00342
Control relay failure
Check output relay
CR244
4-4. Control Van/Controls
4-4-1. Asphalt Display (Screen)
Problem
Cause
Solution/Reference
Asphalt tons/hour not
displayed
Asphalt pump in reverse
or stopped
Select proper direction
and start pump
Asphalt meter not rotating
Check meter
Asphalt tanker empty
Replenish A/C supply
Broken tack wire
Check leads on tack wire
Control fuse blown
Check voltage at terminal
V3 in computer - should
be 24Vdc
See electrical drawing
AA00313
page 4 - 4