TM 5-3895-374-24-2955-2573.5 DIGITALCOMMUNICATIONSA second digit number 2 thru 6 in the part number indicates that the controller has been specified and manufactured with aDigital Communications option.To enable Digital Communications, push the YES key at this display. SeeENABLE ?OPERATOR Flow Chart in Section 7.2.CON LINKTo disable Digital Communications, push the NO key to this display.The host cannot enable digital communications. This can only be accomplished by a key press on the front keypad ofthe controller. Even after communications is enabled, local control is still allowable.During host-controlled operation, the front keypad remains active so that you can override the host and can takecontrol if necessary.The REM indicator light will flash when the communications is enabled. The REM indicator light will continue to flashuntil communications is disabled via the keypad. The host can also turn the REM indicator full on as part of theSTATUS INPUT (PSW) command to inform you that the host is in control. Also included in the host commandstructure is manual control of the controller output(s).ECLIPSE INSTRUMENTATION DIVISIONpage 3-1093