B.
Inspection
1.
The hydraulic pump should be tested and inspected by a qualified specialist. The manufacturer does not provide
repair instructions. Replace the pump with a new one If repairs cannot be effected.
2.
Inspect the electric motor, repair and replace as needed.
3.
Inspect the Sure Flex coupling and replace the coupling if it is damaged or worn.
C.
Assembly
1.
Bolt the electric motor into place on the frame The ground strap must be reinstalled to the motor.
2.
Connect the wiring in the junction box following the markings made at disassembly Place the cover on the junction
box.
3.
Install the Sure Flex coupling bushings onto the shafts and bolt the pump onto the mount.
4.
Align the shafts by shimming the electric motor or adjusting the pump on the mount.
5.
Complete the installation of the shaft coupling following the procedures In Section 3-4-5.
6.
Install the coupling guard.
7.
Install the hydraulic hoses to the pump. Open the valve to the tank.
8.
Inspect all components that have been re-installed Confirm that all fasteners have been torqued.
9.
Remove padlock from the breaker and turn breaker on.