TM 5-3895-374-24-1
GP440FG
A. GENERAL INFORMATION
The Hauck StarJet Burner combines reliable operation with a unique, adjustable flame shaping feature, eliminating the
weight and maintenance problems of ignition tiles. Matching burner flame shape to dryer design is the real secret to overall
dryer efficiency. Some dryers work best with long, narrow, hard driving flame, while other dryers with the same rated
capacity require a short bushy, turbulent flame. Frequently, problems such as overheating of the combustion chamber,
excessive exhaust gas temperatures and poor heat transfer can be eliminated by shaping the burner flame. The burners in
the StarJet series have an extremely wide range of flame shape adjustment.
Burner air consists of primary air (atomizing air) and secondary air. Both are supplied by the Hauck turbo blower. The plant
exhaust air provides the remaining air required for complete combustion and exhaust gas removal.
The StarJet will burn all clean commercial grades of fuel oil, natural gas, and liquid propane. The burner provides a 7 to 1
turndown from the maximum firing rate.
NOTE
Liquid propane and heavier fuels could have less than 7 to 1 turndown.
B. BURNER CAPACITIES
Refer to burner performance table.
Standard Direct Blowers
Burner
Pressure
TRA Blower
Motor
CIMA Fan Rating
Max
Model
Scfm
Osig
Model
HP
ACFM @ 350OF
Btu/Hr
SJ075
983
24
TBA-24-10
10
7,000
12.1 x 106
SJ150
1,496
24
TBA-24-15
15
13,000
22.7 x 106
SJ200
2,350
24
TBA-24-20
20
21,000
37.0 x 106
SJ260
2,870
24
TBA-24-25
25
26,000
45.1 x 106
SJ360
4,350
24
TBA-24-50X
40
40,000
70.4 x 106
SJ520
6,000
24
TBA-24-50
50
53,000
93.3 x 106
High Pressure Direct Drive Blowers
Burner
Pressure
TBA Blower
Motor
CIMA Pan Rating
Max
Model
Scfm
Osig
Model
HP
ACFH @ 350FP
Btu/Hr
SJ075
1,200
36
TBA-36-20
20
8,600
15.2 x 106
SJ150
1,832
36
TBA-36-25
25
16,000
27.9 x 106
SJ200
2,800
37
TBA-36-40
40
23,000
40.5 x 106
SJ260
3,500
36
TBA-36-50
50
28,000
49.3 x 106
SJ360
5,400
37
TBA-36-75
75
43,000
75.6 x 106
SJ520
7,300
36
TBA-36-100
100
55,000
96.8 x 106
SJ580
7,900
36
TBA-36-100
100
68,000
120 x 106
SJ750
9,940
38
TBA-36-125
125
85,000
150 x 106
SJ980
12,220
36
TBA-36-150
150
128,000
200 x 106
Notes:
1.
Oil capacities based on 138,000 Btu per gallon. Viscosity of oil delivered at the burner must be 90 ssu or lower.
2.
Gas capacities based on 1000 Btu per cubic foot and 5 psi manifold inlet pressure with a 3 psi drop across
manifold.
(page 3-501)