TM 5-3895-374-24-1
Serial link
Fault register FLT (W21) Read only
W21,0
INF
Internal speed controller fault (*)
W21,1
SLF
Communication fault
W21,2
-
Reserved
W21,3
SRF
Fault following a TST command
W21,4
USF
Mains too low
W21,5
OSF
Mains too high
W21,6
PHF
Mains phase (s) failure
W21,7
OHF
Speed controller overtemperature
W21 8
SPF
Overspeed (operating with TG)
W21,9
OCF-
Overcurrent()
W21,A
OBF
Overbraking
W21,B
OBF-
Overhauling load current
W21,C
OLF
Motor overload
W21,D
OLF-
Current too low or motor phase failure (*)
W21,E
-
Reserved
W21,F
CRF
Load relay fault (models ? 37 kW)