TM 5-3895-374-10
....................................................................................................................................................... Meters by Average Value
6-MINUTE TIMED VERIFICATIONS
The 6-minute timed scale test provides a convenient method for verifying belt scale calibrations under controlled
conditions. The operator controls the start of the test. During the following 6-minute interval, the average equivalent
aggregate rate, accumulated tons and average belt speed is measured for each scale. This data is automatically printed at
the end of the interval.
NOTE:
Belt speed is printed because the equivalent rate and totals determined by test weights is directly proportional to
belt speed. On generator supplied plants, belt speed is proportional to generator frequency.
1)
Start belt conveyors, run empty for at least 15 minutes and verify or establish a stable zero reading.
2)
Select the METER CALIBRATION BY AVERAGE VALUE display (key strokes 8652). See Figure 8652.5
3)
Optional: Restart the 6-minute Interval by selecting Option 6. At the end of 6 minutes a record verifying zero will
be printed.
4)
Place the asphalt switch in DIVERT LOCKED position! Lower the test weights on the scale.
5)
Restart the 6-minute Interval by selecting Option 6. At the end of 6 minutes a record of the equivalent aggregate
rate will be printed. See Figure 8652.6. Verify this data is (within allowable tolerance) equal to the values
recorded during scale certification.
NOTE:
Left unattended, the computer will continue to repeat these 6-minute tests and printouts.
page F - 75
SYSTEMS Equipment Corp. 8/31/89 Page (40)