TM 5-3895-374-10
options ...........................................................................................................................
MATERIAL USED display
<6>
The Material Use subscreen is shown in Figure 6.0. Note that this screen overlays the right third of the Main Operating
Screen. All data on plant operation continues to be updated every second on the entire screen. The totals shown within
the Material Use subscreen are also updated every second.
The tonnage shown is aligned on the display with the device to which it corresponds. For example, the VirScale tonnage is
shown to the right of the VirScale dTPH rate display. In like manner the volumetric tonnage delivered by each feeder is
shown.
NOTE:
Feeder totals are calculated from the feeder rate signal in use. For feeder rates deduced from the desired
target value the accumulated total is the desired target total and is not a measured value. For volumetrically
measured rates the accumulated total is in volumetric tons. For weighed rates the accumulated total is in
weighed tons.
All usage is in tons accumulated since the totals were last cleared to zero.
The Continuation Option is:
OPTION
KEY
DESCRIPTION
ESCape
ESC
Return to the Main Operating Screen.
page F - 38