TM 5-3895-374-10
options ...............................................................................................................................................EDIT MATERIAL display
<3>
The Edit Material Parameter subscreen is shown in Figure 3.0. Note that this V screen overlays most of the Main
Operating Screen. The MIX Information and INFORMATION displays remain visible and data on the plant operation
continues to be updated every second in these areas.
Shown on the Material display are the following parameters:
Rap
Oil
xx.x
%rA/C
..... (Optional)...The percent of reclaimed asphalt pavement that is reclaimable
asphalt cement.
A/C
Temp
xxx
F
(measured)
..... The pumping temperature of the liquid asphalt as measured automatically
or
every second,
A/C
Temp
xxx
F
(entered)
or as manually entered by the user.
1
Vir
xxx.x
%wet
..... The moisture of the aggregate in the first virgin feed bin.
2
......
......
......
..... NOTE: The moistures for subsequent feed bins are similarly shown.
The Continuation Options are:
OPTION
KEY
DESCRIPTION
ESCape
ESC
Return to the Main Operating Screen.
Edit
.00
Gain access to the data shown so that one or more of the parameters can be
changed. Access cannot be obtained if the DATA KEY is in the DATA LOCKED
position.
SYSTEMS Equipment Corp.
8/31/89
Page (18)
page F - 32