TM 5-3895-374-10options ...............................................................................................................................................EDIT MATERIAL display<3>The Edit Material Parameter subscreen is shown in Figure 3.0. Note that this V screen overlays most of the MainOperating Screen. The MIX Information and INFORMATION displays remain visible and data on the plant operationcontinues to be updated every second in these areas.Shown on the Material display are the following parameters:RapOilxx.x%rA/C..... (Optional)...The percent of reclaimed asphalt pavement that is reclaimableasphalt cement.A/CTempxxxF(measured) ..... The pumping temperature of the liquid asphalt as measured automaticallyorevery second,A/CTempxxxF(entered)or as manually entered by the user.1Virxxx.x%wet..... The moisture of the aggregate in the first virgin feed bin.2....................... NOTE: The moistures for subsequent feed bins are similarly shown.The Continuation Options are:OPTIONKEYDESCRIPTIONESCapeESCReturn to the Main Operating Screen.Edit.00Gain access to the data shown so that one or more of the parameters can bechanged. Access cannot be obtained if the DATA KEY is in the DATA LOCKEDposition.SYSTEMS Equipment Corp.8/31/89Page (18)page F - 32