TM 5-3895-374-10
No.
Panel
Operation
NOTE
Perform a hot shut down (see section 2-16)
NOTE
Correct the problem.
8.
Baghouse Inlet Gas Temperature Exceeds 400°
No.
Panel
Operation
1
D
Burner control panel-select OFF on the Main Flame selector switch.
2
D
Burner control panel-select CLOSED on the Exhaust Shutter selector switch.
3
A
Feeder panel-select DIVERT on the Divert selector switch.
4
B
Motor control panel-press STOP button on Exhaust Fan.
5
D
Burner control panel-press STOP button on Burner Fan.
6
B
Motor control panel-select OPEN on the Drop Out selector switch.
NOTE
Continue to feed aggregate through the plant to lower the plant temperature monitored on the Stack Control
(Panel D). At a temperature of 3250 proceed as follows:
7
Key
Press ESCAPE-targets (1), zero (0), ENTER, ESCAPE.
NOTE
Continue a normal plant shut down rejecting aggregate passing through the drum at the drop out gate in the hot
mix conveyor.
NOTE
Correct the problem.
page 2-124