VARIABLE SETPOINT OPTION - TM-5-3895-374-24-1_72
CONTROLLER CONFIGURATION RECORD

TM-5-3895-374-24-1 Paving Machine Bituminous Material: Crawler Mounted Diesel Engine Driven Manual
Page Navigation
  36    37    38    39    40  41  42    43    44    45    46  
TM 5-3895-374-24-1 GP470FA 4. Press [SET UP] again until the display reads SET UP INPUT2. 5. Press the [FUNCTION] key once.  The lower display will read IN2 HI. 6. Use the ] or ] keys to change the upper display to the setpoint value desired when the burner is firing at 100% (this would be -0.30 for the example given above). 7. Press [FUNCTION] again then use the ] or ] keys to change the upper display to the setpoint value desired when the burner is at low fire (-0.05 for the above example). 8. Press the [SET UP] key again.  The controller display will read SET CONTRL. 9. Press the [FUNCTION] key until the lower display reads SP SRC then use the key to change the upper display to REM. 10. Press the [DISPLAY] to exit the set up mode and return to normal operation. An "L" appearing at the lower right of the controller display indicates that the controller is using its local setpoint for control. Pressing the FUNCTION key will change "L" to "R" and the controller will use the remote setpoint generated by the signal converter module. (page 3-45)