• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
MOUNTING THE UNIT ON CONCRETE BLOCK WALLS
electrical specifications walking air conditioners

TM-5-3895-374-24-1 Paving Machine Bituminous Material: Crawler Mounted Diesel Engine Driven Manual
Page Navigation
  468    469    470    471    472  473  474    475    476    477    478  
TM 5-3895-374-24-1 ELECTRICAL WIRING-CONTROL CIRCUIT Five (5) wires should be run from thermostat subbase to the 24V terminal board in unit Use 18 gauge copper color coded thermostat wiring Thermostat Wiring: a) Cooling Only refer to parts list for order No Connect (R), (Y and (G) terminals on thermostat, to (R), (Y) and (G) terminals on unit terminal board b) Cooling/Heating: refer to parts list for order No (1-stage cooling and 1-stage heating thermostat). 1 Connect (R), (Y), (G) and (W,) terminals on thermostat, to (R), (Y), (G), and (W,) terminals on unit terminal board 2 Jumper (W,) and (W2) on unit terminal board c) Cooling/Heating refer to parts list for order No (1-stage cooling and 2-stage heating thermostat). Connect (R), (Y), (G), (W,) and (W2) terminals on thermostat to corresponding (R), (Y), (G), (W,) and (W2) terminals on unit terminal board (page 3-489)