TM 5-3895-374-24-1GP255FHTURBO BLOWERTROUBLESHOOTING CHECKLISTSymptomCauseCorrection1. Motor Will NotA. Open Circuited-Check Continuity OfStartWiringB. One Phase Not Con--Check Continuity Ofnected (Motor Hums butWiringDoesn’t Turn)-Check For Open Breakersor Blown Fuses-Check Proper Terminal WiringC.Motor Burned Out-Check Last Known OperatingLoad For Possible OverloadConditions-Check Ambient Operating Conditions2. Motor Blows FusesA. Grounded Internal-Replace MotorWhen Starting IsWindingAttemptedB.Improper Terminal-RewireWiring3. Motor OperatesA High Ambient-Class B Insulation RatedVery HotTemperatureFor Maximum Service At 1040 FAmbientB.Motor Running Over--Check For Excessive LeaksloadedIn The System or Blower-Check Design Capacity AgainstSystem RatingC.Improper Voltage Applied-Check Voltage AgainstTo Terminals or ImproperlyRatingWired-Check Wiring ConnectionsD.Interference Between the-Replace MotorRotor and StatorE Short Circuited Windings-Replace MotorIn Motor4. Generated PressureA.Improperly Located-Check For Improper LocationLower Than Rated Pressure GaugeLocation Downstream Of Elbows,ValueButterfly Valves, etc.B.Blower Operating Above-Check For Excessive Leaks InDesign Capacity (MotorThe System or BlowerOverloaded)-Check Design Capacity AgainstSystem Rating-Check For Missing Orifice Plates-Check Burner Discharge For AreasOpened By Excessive HeatC.Impeller Running Back--Rewire Motor to ReversewardsRotationD.Impeller Running Correctly-Replace Impeller With One Forbut Built For Wrong Dir-Proper Direction of Rotationection of RotationGP325FAHAUCK MANUFACTURING CO.,P. O. Box 90, Lebanon, PA 17042 717-272-3051Fax 717-273-9882 Telex 671-1457(page 3-549)