TM 5-3895-374-24-1
INSTRUCTIONS
TURBO BLOWERS
Fig 1 - Hauck Fiberglass Turbo Blower
TABLE OF CONTENTS
Subject
Page
A.
General Information................................................................................................................................... 1
B.
Installation.................................................................................................................................................. 1
C
Operation ................................................................................................................................................... 4
D
Maintenance .............................................................................................................................................. 5
Troubleshooting Checklist .................................................................................................................... GP325
A. GENERAL INFORMATION
The Hauck Fiberglass Turbo Blower is designed for use on any application requiring low pressure air at constant pressure
(12 to 40 ozs.) This blower employs a unique integral molded scroll design and a turbine impeller to produce increased
operating efficiency. These blowers are thoroughly tested prior to shipment to assure satisfactory performance when
installed.
B. INSTALLATION
IMPORTANT
Always lift the blower by the base or motor lifting eye, never by the casing outlet or Inlet flange
connections since they are not designed to support the weight of the motor and base
assembly.
These Instructions are intended to serve as guidelines covering the installation, operation, and maintenance of Hauck
equipment While every attempt has been made to ensure completeness, unforeseen or unspecified applications, details
and variations may preclude covering every possible contingency WARNING. TO PREVENT THE POSSIBILITY OF
SERIOUS BODILY INJURY, DO NOT USE OR OPERATE ANY EQUIPMENT OR COMPONENT WITH ANY PARTS
REMOVED OR ANY PARTS NOT APPROVED BY THE MANUFACTURER Should further information be required or
desired or should particular problems arise which are not covered sufficiently for the purchasers purpose contact Hauck
Mfg Co
HAUCK MANUFACTURING CO., P.O. Box 90, Lebanon, PA 17042 717-272-3051
GP255FH
9/90
Fax 717-273-9882 Telex 671-1457
EA1-8-
(page 3-539)