TM 5-3895-374-1012. Miscellaneous Set Up Procedures(See Figures 2-15, 2-29, 2-30, 2-31 and 2-32)ItemProcedure1Position the calibration tank as per the site layout Figure 2-29. The valve end should be positioned toward the asphalt tanker.2Assemble the upper portion of the tank frame to the lower portion and install the bolts and tighten. See Figure 2-30.3Unbolt the lower frame from the tank and suspend the tank on the chains provided. See Figure 2-30.4Remove the retainer bolts holding the test weights in position. See Figure2-30.5The electrical power cables can be unwrapped from their transport storage positions andconnected to the control van. The cables are to run parallel to each other in straight lines. See Figure 2-31. Lay out thepower cables in the following order: Surge Bin (laid out and connected during surge bin set up)BaghouseDedrummer/MelterAsphalt TankerDrum MixerFeed ConveyorFour Bin Feeder6The electrical control cables can be unwrapped from their transport storage positions and connected to the control van. These cables are to run parallel-to each other in straight lines. See Figure 2-32. Lay outthe control cables in the same order as power cables.7Hydraulic power pack. Store this unit on or near the goose neck of the control trailer. It may be required for re-leveling of any equipment that settles during operation.8Install the fines blower hose (stored in the basket on the dedrummer) from the blower on the baghouse to the drum mixer. See Figure 2-15.page 2 - 50