TM 5-3895-374-10
options. . utilities.......................................................................................................................... USER OPTIONS display
<8>
<8>
The User Options display is shown in Figure 88.0Note that even though this display overwrites the entire Main Operating
Display, the plant operation and data gathering continue uninterrupted.
Lines 1 through 4 of the display shown define the user selected process options currently in effect. By editing this display
the user can reconfigure these options.
The available options are:
1 - Virgin Aggregate measured by scale or by volume
2 - Recycle Aggregate measured by scale or by volume
3 - A/C temperature is measured by probe or entered by user
4 - A/C blend is a X of total mix or total aqqreqate
The Continuation Options are:
OPTION
KEY
DESCRIPTION
ESCape
ESC
Return to the previous display.
Edit
.00
Gain access to the options shown on the display so that they can be changed. Access
can not be obtained if the DATA KEY is in the DATA LOCKED position.
Print
9
Print this screen display. The printer must be turned ON and SELECTed.
page F - 99
SYSTEMS Equipment Corp. 8/31/89 Page (52)