TM 5-3895-374-10
HAZARD
DESCRIPTION
RECOMMENDATION
High voltage
Power cables.
Avoid contact when energized.
electrical
Maintain in good condition.
Use cable supports provided.
Do not perform repair work
without a qualified electrician.
Fluids under
Hydraulic cylinders, lines and
Maintain lines in good
pressure
valves. Diesel lines. Heat
operating condition. Wear
transfer lines.
protective clothing while
operating the plant (gloves,
coveralls, safety glasses, hard
hat).
Compressed air
The trailer air brake system is
Maintain system in good
comprised of air lines, tanks
operating condition. Release
and valves which activate the
air pressure prior to repairing
trailer brakes.
the system.
Confined space
The asphalt tank is 10 feet in
Restrict entry. Repair by
diameter with one manhole.
qualified repair personnel only,
Entry may be required to
after proper procedures have
locate leaks in the heating
been followed.
coils and to effect repairs.
Flammable and
A diesel tank is mounted on
Inspect and maintain as per
combustible
this unit. The liquid asphalt
manuals.
materials
has a flash point of 4500 F.
The heat transfer oil has a
flash point of 5400 F.
9.Asphaft Tanker
HAZARD
DESCRIPTION
RECOMMENDATION
Noise
Steady noise levels exceeding
Use of ear protection.
85 dba may be caused by the
burner blower. An air cylinder
mounted on the tanker
exhausts compressed air
when operational and will
cause intermittent noise.
page 1-10