Control System Interlocks

TM-5-3895-374-24-2 M081 Asphalt Mixing Plant Manual
Page Navigation
  708    709    710    711    712  713  714    715    716    717    718  
TM 5-3895-374-24-2 4-7.  Baghouse Problem Cause Solution/Reference Motor tripping on auger Auger overloaded Product not clearing from system System not clearing Overload of dust Blower not operating Air lock not running Fines blower line from airlock to drum mixer plugged Bags not cleaning Select AUTO or baghouse clean Air compressor not operating Pulse system not operating Air pressure too low on cleaning Differential pressure high Bags dirty Exhaust air flow too high Bags wet, caked or coated Fire shutter not operating Air compressor OFF Low air pressure Solenoid valve failed Shutter door jammed Baghouse temperature Reads high page 4 - 22