HEATER OPERATIONAL SAFEGUARDS - TM-5-3895-374-24-2_541

TM-5-3895-374-24-2 M081 Asphalt Mixing Plant Manual
Page Navigation
  475    476    477    478    479  480  481    482    483    484    485  
TM 5-3895-374-24-2 FLAME FAILURE If  your  heater  has  experienced  a  FLAME  FAILURE,    push  the  react  button  on  the  programmer and  operate  the  burner  from  a  normal  start  position  to  determine  the  cause  of  the  problem.    A FLAME FAILURE indication can be caused by either of the following conditions: - the flame failed to ignite during the ignition cycle. - the flame ignited during the ignition cycle but the Flame Safeguard System failed to  detect  the  flame.    SECTION  6.1;    OPERATION  PROGRAMMER  contains  a procedure for determining which component is failing. You  call  determine  whether  or  not  you  have  a  flame  during  ignition  by  shading  your  eye  and looking through the peephole on tile burner during the ignition (cycle).  You must. shade your eye well  to  see  the  gas  pilot  flame.  If  you  can  see  a  flame.    then  the  problem  is  probably  with  the Flame Safeguard System. page 3 - 1174