FLAME AMPLIFIER SELECTION
WARRANTIES, EXCLUSIVE REMEDIES, AND LIMITATION OF DAMAGES - TM-5-3895-374-24-2_522

TM-5-3895-374-24-2 M081 Asphalt Mixing Plant Manual
Page Navigation
  456    457    458    459    460  461  462    463    464    465    466  
TM 5-3895-374-24-2 The flame amplifier module is installed in the second set   of   guide   channels   found   in   the   EB700   FLAME- MONITOR Chassis. It is marked "AMPLIFIER MODULE". Do not force the module into position. CAUTION:      Remove   power   from   the   wiring   base before trying to replace the Flame Amplifier Module. IMPORTANT                                                                                                                                                                                Terminal Wiring Base When    wiring    to    the    FLAME-MONITOR    wiring    base, scanner   terminal   S2   must   be   grounded   when   using flame rod on photocell scanner.  When using an infrared scanner   (48PT2),   ground   S2   on   all   EB700’s   labeled "ENG  CODE  00".    All  other  ENG  CODE  models  do  not require  that  S2  be  grounded.    Do  not  ground  S2  when using ultra violet scanners. 3 page 3 - 1155