• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 9 OIL NOZZLE FLOW RATE CHARTS
Table 10 Gas Burner Orifice Sizing Information (See pages 32, Fig.  33 for side orifice detail.)

TM-5-3895-374-24-2 M081 Asphalt Mixing Plant Manual
Page Navigation
  293    294    295    296    297  298  299    300    301    302    303  
TM 5-3895-374-24-2 Direct Spark Oil Ignition Adjustments 1. The  ignitor  assembly  should  be  removed  and  cleaned regularly.  The porcelain insulators should be kept clean and must be replaced if cracked. 2. The   spark   gap   must   be   set   in   accordance   with   the dimensions  noted.    (Refer  to  Figs.  30,  31,  32).    Ensure that the distance between the electrodes and the nozzle (or diffuser) is greater than the spark gap. 3. The electrodes should not extend closer than 1/8” to the spray angle of the nozzle to prevent carboning.  A nozzle spray angle check card is available and may be used to check electrode position. 4. The high tension wires and clips between the transformer and ignitor electrodes should be checked periodically for deterioration. Figure 30 Figure 31 Figure 32 Figure 33 (page 3-984)