TM 5-3895-374-24-1 GP255FH NOTE In order to ensure an effective air seal, it is Important that a suitable caulking (we recommend "STRIP  CAULK"  by  3M)  be  placed  between  the  outlet  adapter  and  the  casing  halves  for  a short distance in each direction. Suggested approximate area of caulking is shown shaded m Figure 5. Replace the self-tapping screws (22) which hold the front half of the casing to the outlet adapter. IMPORTANT It is important to reinsert the key before attempting to tighten the impeller setscrews. Failure to  do  so  will  prevent  proper  tightening  of  the  key  setscrew.  It  Is  also  Imperative  that  the sequence  and  torquing  procedure  outlined  be  followed  exactly.  Failure  to  sufficiently  tighten the setscrews may allow the Impeller to further loosen during operation of  the  blower,  while excessive tightening may damage the setscrews as well as impair their effectiveness. BLOWER HUB LOCKING MECHANISM Fig. 6 (page 3-545)