Fig 4-UDC3000 Temperature Controller
LOWER DISPLAY(FUNCTION)

TM-5-3895-374-24-1 Paving Machine Bituminous Material: Crawler Mounted Diesel Engine Driven Manual
Page Navigation
  15    16    17    18    19  20  21    22    23    24    25  
TM 5-3895-374-24-1 GP467FB 12.  [MAN/AUTO] KEY: Alternately selects Manual or Automatic control mode. 13.  [AUTO TUNE] KEY: Starts the Automatic Tuning procedure.  KEY ERROR appears If Auto Tune disabled. 14.  [RUN/HOLD] KEY: Not used. 15.  [?] KEY: Used to increase Set Point, % Output or Configuration values. 16.  [ ] KEY: Used to decrease Set Point, % Output or Configuration values. EXAMPLE 1: CHANGING THE SET POINT Press the [LOWR DISP] key until SP and the current set point appears in the lower display Press and hold the [?] key to increase the set point value.  To make changes more quickly, press the [ ] key while holding [ ] key.  This will shift the changing digit one place to the left.  To decrease the set point value, reverse the above procedure. EXAMPLE 2: POSITIONING THE CONTROL MOTOR IN THE MANUAL MODE Press the [AUTO/MAN] key to place the Controller in the Manual Mode.  The MAN indicator will come ON and the lower display will automatically change to show % OUT. Press and hold the [?] key to increase the % Output value To make changes more quickly press the [ ] key while holding [?] key This will shift the changing digit one place to the left. To decrease the % Output value, reverse the above procedure. EXAMPLE 3: CHANGING THE ALARM SET POINT Press and hold the [SET UP] key until the display reads SETUP ALARMS. Press  the  [FUNC]  key  once  to  change  the  lower  display  to  A1S1  VAL.    The  upper  display  will  show  the  current alarm set point.  Use the [?] or [ ] arrow key to change to the desired set point Press the [LOWR DISP] key to exit the Set Up mode and return the controller to normal operation. CAUTION If  the  process  system,  such  as  a  rotary  dryer  application,  has  a  fabric  filter  dust  collector  (baghouse), consult the manufacturer for recommended baghouse temperature limitations. H.  CONFIGURATION RECORD SHEET Hauck part number 48736; Honeywell model DC3004-0-OOA-1-00. Cold junction jumper in position W1.  Alarm relay jumper In position W7 See page 3-21 of instruction manual for jumper locations. (page 3-18)







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.